Elmo Rietschle vacuum pumps, compressors, combined vacuum and pressure pumps, technical specifications and support for current and older models.
Vacuum Pumps UK can help identify an installed Elmo Rietschle or Gardner Denver pump, provide a quotation, arrange service support and spare parts, or compare suitable DVP alternatives where the application makes comparison worthwhile.

Tell us the model, specification and electrical supply required and we will provide a quotation or confirm the information needed.
Use the current and older model tables below, or send us a clear photograph of the complete pump nameplate.
Our sister company VacAir Superstore supports Elmo Rietschle pumps with servicing, vanes, filters and spare parts.
Where appropriate, we can compare Elmo Rietschle pumps with carefully selected DVP options for the application.
Our sister company,
VacAir Superstore
,
provides workshop servicing, replacement carbon vanes, filters, service kits and spare parts for current and older Elmo Rietschle and Gardner Denver pumps.
Workshop repairs, fault diagnosis and complete overhauls for current and older Elmo Rietschle vacuum pumps and blowers, supported by experienced engineers and fast UK turnaround.
Replacement components, maintenance parts and service kits for current and legacy Elmo Rietschle and Gardner Denver pump models, backed by expert technical support.
Precision replacement carbon vanes for Elmo Rietschle dry-running vacuum pumps, pressure pumps and combined vacuum and pressure models.
Inlet filters, exhaust filters, oil separators and replacement filter elements designed to protect pump performance, reliability and service life.
We can supply Elmo Rietschle equipment and, where useful, compare it with carefully selected DVP models. Comparisons are based on pumping speed, vacuum or pressure level, motor power, operating duty, installation and process conditions.
The range comparisons below are useful starting points. Final selection must always be confirmed against the complete application and technical specification.
V-VTE, V-VTN, V-VTA, V-VTR, VFT, DTE, DTA, DFT, DLT, KTN, KTR, KLT and KTA
Dry-running rotary vane vacuum pumps
Dry-running rotary vane vacuum pumps
VLR, DLR, claw vacuum pumps
Oil-free claw vacuum technology
Oil-free claw vacuum pumps
VC, VCE, VCEH, VGA and VCA oil-lubricated pumps
Oil-lubricated rotary vane vacuum pumps
Oil-lubricated rotary vane vacuum pumps
Important: These are range-level starting points, not confirmed drop-in replacements. Port sizes, dimensions, electrical requirements, ultimate vacuum, pressure capability, noise and continuous-duty suitability must be checked.
Choose a pump type below to jump directly to its specification table. Older models are retained because many remain installed and continue to require identification, servicing, parts or replacement.
Send a clear photograph of the complete nameplate. Include the model, serial number, voltage, frequency and suffix letters, and tell us whether you need a new pump, repair, spare parts or help selecting a suitable comparison.
Current VTE, VTN, VTA and VTR dry-running rotary vane vacuum pump models.
| Model | M3/Hr 50 / 60Hz | Max Vacuum mbar Abs 50 / 60 Hz |
Motor Size Kw 50 / 60 Hz |
|
|---|---|---|---|---|
| 3PH | 1PH | |||
| VTE3 | 3.5/4.2 | 150 | 0.12/0.45 | 0.12/0.45 |
| VTE6 | 6.0/7.2 | 150 | 0.25/0.30 | 0.25/0.30 |
| VTE8 | 8.0/9.6 | 150 | 0.37/0.44 | 0.35/0.42 |
| VTE10 | 10.0/12.0 | 150 | 0.37/0.44 | 0.37/0.44 |
| VTN16 | 17/20.5 | 150 | 0.55/0.65 | 0.55/0.65 |
| VTN26 | 27/32 | 150 | 0.75/0.90 | 0.75/0.90 |
| VTN41 | 42/50.4 | 150 | 1.5/1.8 | |
| VTA60 | 55/66 | 150 | 1.5/1.8 | |
| VTA80 | 77/92 | 150 | 2.2/2.6 | |
| VTR100 | 100/120 | 150 | 3.0/3.4 | |
| VTR140 | 130/155 | 150 | 4.0/4.8 | |
Current DTE, DTN, DTA and DTR dry-running rotary vane pressure pump models.
| Model | M3/Hr 50 / 60Hz |
Max Pressure mbar Abs 50 / 60 Hz | Motor Size Kw 50 / 60 Hz |
|
|---|---|---|---|---|
| 3PH | 1PH | |||
| DTE6 | 6.0/7.2 | 1000 | 0.25/0.30 | 0.25/0.30 |
| DTE8 | 8.0/9.6 | 1000 3 ph/600 1 ph | 0.37/0.44 | 0.25/0.30 |
| DTE10 | 10.0/12.0 | 1000 3 ph/800 1 ph | 0.37/0.44 | 0.37/0.44 |
| DTN16 | 17/20.5 | 700/600 | 0.55/0.65 | 0.55/0.65 |
| 17/20.5 | 1000 | 0.75/0.9 | 0.75/0.90 | |
| DTN26 | 26.0/31.2 | 600/500 | 0.75/0.90 | 0.75/0.90 |
| 26.0/31.2 | 1000 | 1.1/1.3 | 1.10/1.30 | |
| DTN41 | 43.5/52.2 | 700/600 | 1.5/1.8 | |
| 43.5/52.2 | 1000 | 1.85/2.2 | ||
| DTA60 | 58/70 | 700/500 | 2.2/2.6 | |
| 58/70 | 1400/1500 | 3.0/3.6 | ||
| DTA80 | 73/88 | 900/700 | 3.0/3.6 | |
| 73/88 | 1500 | 4.0/4.8 | ||
| DTR100 | 100/120 | 1000 | 4.0/4.8 | |
| 100/120 | 1500/1400 | 5.5/6.5 | ||
| DTR140 | 130/155 | 1000 | 5.5/6.5 | |
| 130/155 | 1500 | 7.5/9.0 | ||
Current KTN, KTA and KTR combined vacuum and pressure pump models.
| Model | M3/Hr 50 / 60Hz |
Max Vacuum mbar Abs 50 / 60 Hz |
Max Pressure mbar Abs 50 / 60 Hz | Motor Size Kw 50 / 60 Hz |
|---|---|---|---|---|
| 3PH | ||||
| KTN16 | 17/19.8 | 600 | 600 | 0.75/0.90 |
| KTN26 | 26/31.5 | 600 | 600 | 1.1/1.3 |
| KTN41 | 42.5/51.0 | 600 | 600 | 1.85/2.2 |
| KTA60/1 | V=54.3 P= 54.0 (50Hz) | 600 | 600 | 2.2/2.6 |
| V=64.1 P = 63.7 (60Hz) | 600 | 700 | 3.0/3.6 | |
| KTA60/2 | V=40 P=57.6 (50Hz) | 600 | 600 | 2.2/2.6 |
| V=47.2 P=67.9 (60Hz) | 600 | 700 | 3.0/3.6 | |
| KTA60/3 | V=59.5 P=45 (50Hz) | 600 | 600 | 2.2/2.6 |
| V=70.2 P=53.1 ( 60Hz ) | 600 | 700 | 3.0/3.6 | |
| KTA80/1 | V=70 P=68.5 (50Hz) | 600 | 600 | 3.0/3.6 |
| V=82.6 P=80.8 (60Hz) | 600 | 700 | 4.0/4.8 | |
| KTA80/2 | V=50.5 P=73.0 (50Hz) | 600 | 600 | 3.0/3.6 |
| V=60 P=86.1 (60Hz) | 600 | 700 | 4.0/4.8 | |
| KTA80/3 | V=74.5 P=57.0 (50Hz) | 600 | 600 | 3.0/3.6 |
| V=87.9 P= 67.3 (60Hz) | 600 | 700 | 4.0/4.8 | |
| KTR100 | V=103.6 P= 110 (50Hz) | 600 | 600 | 5.5/6.5 |
| V= 127.9 P= 136.5 (60Hz) | ||||
| KTR140 | V= 131.3 P= 136.4 (50Hz) | 600 | 600 | 7.3/8.0 |
| V= 156.1 P= 161.3 (60Hz) | ||||
| KTR140 DVV | V= 57/78 P=76 (50Hz) | 600 | 600 | 7.5/9.0 |
| V= 71.7/95 P=91.9 (60Hz) |
Older VLT, VTA, VTB and VFT dry-running vacuum pump models retained for identification and support.
| Model | M3/Hr 50 / 60Hz |
Max Vacuum mbar Abs 50 / 60 Hz |
Motor Size Kw 50 / 60 Hz |
|
|---|---|---|---|---|
| 3PH | 1PH | |||
| VTE3 | 3.5/4.2 | 150 | 0.12/0.145 | 0.12/0.45 |
| VTE6 | 6.0/7.2 | 150 | 0.25/0.30 | 0.25/0.30 |
| VTE8 | 8.0/9.6 | 150 | 0.37/0.44 | 0.35/0.42 |
| VLT10 | 11.7/13.5 | 150 | 0.37/0.44 | 0.37/0.44 |
| VLT15 | 17/20.5 | 150 | 0.55/0.65 | 0.55/0.65 |
| VLT25 | 25.8/30.7 | 150 | 0.75/0.90 | 0.75/0.90 |
| VLT40 | 42/50.4 | 150 | 1.5/1.8 | |
| VTA60 | 55/66 | 150 | 1.5/1.8 | |
| VTA80 | 77/92 | 150 | 2.2/2.6 | |
| VTA100 | 98/118 | 150 | 3.0/3.4 | |
| VTA140 | 128/153 | 150 | 4.0/4.8 | |
| VTB180 | 170/200 | 150 | 4.0/4.8 | |
| VTB250 | 250/300 | 150 | 5.5/6.5 | |
| VTB340 | 350/410 | 150 | 11.0/13.0 | |
| VFT25 | 25/30 | 150 | 0.75/0.90 | 1.00/1.10 |
| VFT40 | 40/48 | 150 | 1.10/1.30 | 1.30/1.50 |
| VFT60 | 60/72 | 150 | 1.50/1.80 | |
| VFT80 | 80/96 | 150 | 2.20/2.60 | |
| VFT100 | 100/120 | 150 | 3.00/3.60 | |
| VFT140 | 140/168 | 150 | 4.00/4.80 | |
| VFT180 | 180/216 | 150 | 5.50.6.60 | |
| VFT250 | 250/300 | 150 | 7.50/9.00 | |
| VFT340 | 340/408 | 150 | 11.0/13.5 | |
| VFT500 | 500/600 | 150 | 15.0/18.5 | |
Older DLT, DTA, DTB and DFT dry-running compressor models retained for technical reference.
| Model | M3/Hr 50 / 60Hz |
Max Pressure mbar Abs 50 / 60 Hz |
Motor Size Kw 50 / 60 Hz |
|
|---|---|---|---|---|
| 3PH | 1PH | |||
| DTE3 | 3.5/4.2 | 1000 | 0.12/0.14 | 0.12/0.14 |
| DTE6 | 6.0/7.2 | 1000 | 0.25/0.30 | 0.25/0.30 |
| DTE8 | 8.0/9.6 | 1000 3 ph/600 1 ph | 0.37/0.44 | 0.25/0.30 |
| DLT10 | 11.3/13.0 | 700/600 | 0.37/0.44 | 0.37/0.44 |
| 11.3/13.0 | 1000 | 0.45/0.55 | 0.45/0.55 | |
| DLT15 | 17/20.5 | 700/600 | 0.55/0.6 | 0.55/0.60 |
| 17/20.5 | 1000 | 0.75/0.9 | 0.75/0.90 | |
| DLT25 | 26.0/31.2 | 700/800 | 0.75/0.90 | 0.75/0.90 |
| 26.0/31.2 | 1000 | 1.1/1.3 | 1.1/1.3 | |
| DLT40 | 43.5/52.2 | 700/600 | 1.5/1.8 | |
| 43.5/52.2 | 1000 | 1.85/2.2 | ||
| DTA50 | 52/62 | 900/600 | 2.2/2.6 | |
| 52/62 | 1500 | 3.0/3.6 | ||
| DTA60 | 58/70 | 700/500 | 2.2/2.6 | |
| 58/70 | 1500 | 3.0/3.6 | ||
| DTA80 | 73/88 | 900/700 | 3.0/3.6 | |
| 73/88 | 1500 | 4.0/4.8 | ||
| DTA100 | 97/116 | 1000/800 | 4.0/4.8 | |
| 97/116 | 1500 | 5.5/6.5 | ||
| DTA140 | 126/151 | 1200/900 | 5.5/6.5 | |
| 126/151 | 1500 | 7.5/9.0 | ||
| DTB180 | 175/210 | 800/700 | 5.5/6.5 | |
| 175/210 | 1400/1300 | 7.5/9.0 | ||
| 175/210 | 2000 | 11.0/13.0 | ||
| DTB250 | 250/300 | 850/800 | 7.5/9.5 | |
| 250/300 | 1600/1500 | 11.0/13.0 | ||
| 250/300 | 2000 | 15.0/18.0 | ||
| DTB340 | 350/420 | 1000 | 15.0/18.0 | |
| 350/420 | 1600/1500 | 18.5/22.0 | ||
| 350/420 | 1800 | 22.0/26.0 | ||
| DFT25 | 25/30 | 700/600 | 0.75/0.90 | 1.00/1.10 |
| 1300/1200 | 1.10/1.30 | 1.30/1.50 | ||
| 1500/0.00 | 1.50/1.80 | |||
| DFT40 | 40/48 | 550/600 | 1.10/1.30 | 1.30/1.50 |
| 1050/1000 | 1.50/1.80 | |||
| 1500/1200 | 2.20/2.60 | |||
| DFT60 | 60/72 | 550/0.00 | 1.50/0.00 | |
| 1100/700 | 2.20/2.60 | |||
| 1500/1200 | 3.00/3.60 | |||
| DFT80 | 80/96 | 500/0.00 | 2.20/0.00 | |
| 900/800 | 3.00/3.60 | |||
| 1500/1200 | 4.00/4.80 | |||
| DFT100 | 100/120 | 600/500 | 3.00/3.60 | |
| 1000/900 | 4.00/4.80 | |||
| 1500/1200 | 5.50/6.60 | |||
| DFT140 | 140/168 | 750/600 | 5.50/6.50 | |
| 1500/1200 | 7.50/9.00 | |||
| DFT180 | 180/216 | 800/700 | 7.50/9.00 | |
| 1500/1200 | 11.0/13.5 | |||
| DFT250 | 250/300 | 600/0.00 | 7.50/0.00 | |
| 1050/900 | 11.0/13.5 | |||
| 1500/1200 | 15.0/18.5 | |||
| DFT340 | 340/408 | 500/500 | 11.0/13.5 | |
| 1300/1000 | 15.0/18.5 | |||
| DFT500 | 500/600 | 700/600 | 18.5/22.0 | |
| 1300/1000 | 22.0/26.5 | |||
Older KLT and KTA combined vacuum and pressure models retained for identification and support.
| Model | M3/Hr 50 / 60Hz |
Max Vacuum mbar Abs 50 / 60 Hz |
Max Pressure mbar Abs 50 / 60 Hz |
Motor Size Kw 50 / 60 Hz |
|---|---|---|---|---|
| 3PH | ||||
| KLT15 | 16.7/20.0 | 600 | 600 | 0.75/0.90 |
| KLT25 | 26/31 | 600 | 600 | 1.1/1.3 |
| KLT40 | 42/50.4 | 600 | 600 | 1.85/2.2 |
| KTA50/1 | V=48.5 P=48 (50Hz) | 600 | 600 | 2.2/2.6 |
| V=57.2 P=56.6 (60Hz | 700 | 600 | 3.0/3.6 | |
| KTA50/2 | V=38.0 P=51.0 (50Hz) | 600 | 600 | 2.2/2.6 |
| V=44.8 P=60.2 (60Hz) | 700 | 600 | 3.0/3.6 | |
| KTA60/1 | V=54.3 P= 54.0 (50Hz) | 600 | 600 | 2.2/2.6 |
| V=64.1 P = 63.7 (60Hz) | 700 | 600 | 3.0/3.6 | |
| KTA60/2 | V=40 P=57.6 (50Hz) | 600 | 600 | 2.2/2.6 |
| V=47.2 P=67.9 (60Hz | 700 | 600 | 3.0/3.6 | |
| KTA60/3 | V=59.5 P=45 (50Hz) | 600 | 600 | 2.2/2.6 |
| V=70.2 P=53.1 (60Hz) | 700 | 600 | 3.0/3.6 | |
| KTA80/1 | V=70 P=68.5 (50Hz) | 600 | 600 | 3.0/3.6 |
| V=82.6 P=80.8 (60Hz) | 700 | 600 | 4.0/4.8 | |
| KTA80/2 | V=50.5 P=73.0 (50Hz) | 600 | 600 | 3.0/3.6 |
| V=60 P=86.1 (60Hz) | 700 | 600 | 4.0/4.8 | |
| KTA80/3 | V=74.5 P=57.0 (50Hz) | 600 | 600 | 3.0/3.6 |
| V=87.9 P= 67.3 (60Hz) | 700 | 600 | 4.0/4.8 | |
| KTA100/1 | V=92.1 P=90.0 (50Hz) | 600 | 600 | 4.0/4.8 |
| V=108.7 P=106.2 (60Hz) | 700 | 600 | 5.5/6.5 | |
| KTA100/2 | V=67.5 P=94.2 (50Hz) | 600 | 600 | 4.0 4.8 |
| V=79.6 P=111.2 (60Hz) | 700 | 600 | 5.5/6.5 | |
| KTA100/3 | V=100.1 P=75.0 (50Hz) | 600 | 600 | 4.0/4.8 |
| V=118.2 P=111.2 (60Hz) | 700 | 600 | 5.5/6.5 | |
| KTA140/1 | V=108 P=108 (50Hz) | 600 | 600 | 5.5/6.5 |
| V=127.4 P=127.4 (60Hz) | 700 | 600 | 7.5/9.0 | |
| KTA140/2 | V=81.5 P=115.0 (50Hz) | 600 | 600 | 5.5/6.5 |
| V=96.2 P=135.7 (60Hz) | 700 | 600 | 7.5/9.2 | |
| KTA140/3 | V=118 P=95 (50Hz) | 600 | 600 | 5.5/6.5 |
| V=139.2 P=112.1 (60Hz) | 700 | 600 | 7.5/9.2 |
Current claw vacuum, pressure and combined-duty models.
| Model | M3/Hr 50 / 60Hz |
Max Vacuum mbar Abs 50 / 60 Hz |
Motor Size Kw 50 / 60 Hz |
|---|---|---|---|
| 3PH | |||
| C-VLR60 | 60/72 | 100 | 1.1/1.3 |
| C-VLR100 | 100/120 | 150 | 2.2/2.6 |
| C-VLR150 | 150/180 | 100 | 3.0/3.6 |
| C-VLR250 | 235/282 | 200 | 4.0/4.8 |
| C-VLR251 | 211/255 | 200 | 4.0/4.8 |
| C-VLR301 | 290/350 | 150 | 5.5/6.5 |
| C-VLR401 | 400/480 | 200 | 7.5/9.0 |
| C-VLR501 | 500/600 | 200 | 11.0/12.6 |
| C-VLR501 | 950/1140 | 200 | 18.5/22.0 |
Current and older claw compressor models retained for technical comparison.
| Model | M3/Hr 50 / 60Hz |
Max Pressure mbar Abs 50 / 60 Hz |
Motor Size Kw 50 / 60 Hz |
|---|---|---|---|
| 3PH | |||
| C-DLR60 | 56/68 | 1800/2000 | 3.0/3.6 |
| C-DLR100 | 100/120 | 800 | 3.00 |
| 1400 | 4.0/4.8 | ||
| 2000/2200 | 5.5/6.5 | ||
| C-DLR150 | 142/170 | 1200/1000 | 5.5/6.5 |
| 2000/1800 | 7.5/9.0 | ||
| C-DLR250 | 235/282 | 1000/800 | 7.5/9.0 |
| 2000/1800 | 11.0/13.0 | ||
| 0/2200 | 0.0/18.0 | ||
| C-DLR300 | 300/360 | 600/0.0 | 7.5/9.0 |
| 1400/1200 | 11.0/13.0 | ||
| 2200/2200 | 15.0/18.0 | ||
| C-DLR301 | 270/320 | 2000/0.0 | 15.0/0.0 |
| 0.00/1800 | 0.00/18.0 | ||
| C-DLR400 | 385/462 | 800/600 | 11.0/13.0 |
| 1400/1200 | 15.0/18.0 | ||
| 1800/1600 | 18.5/22.0 | ||
| 2000/2000 | 22.0/26.0 | ||
| C-DLR401 | 400 | 1800 | 22 |
| C-DLR500 | 500/600 | 800/800 | 15.0/18.0 |
| 1200/1200 | 18.5/22.0 | ||
| 1600/1600 | 22.0/26.0 | ||
| 2000/2000 | 30.0/36.0 | ||
| C-DLR501 | 500/600 | 2000/2000 | 30.0/36.0 |
Older claw vacuum pump models retained because many remain installed in industry.
| Model | M3/Hr 50 / 60Hz |
Max Vacuum mbar Abs 50 / 60 Hz |
Motor Size Kw 50 / 60 Hz |
|---|---|---|---|
| 3PH | |||
| C-VLR100 | 100/120 | 150 | 1.1/1.3 |
| C-VLR150 | 150/180 | 100 | 2.2/2.6 |
| C-VLR250 | 235/282 | 200 | 3.0/3.6 |
| C-VLR251 | 211/255 | 200 | 4.0/4.8 |
| C-VLR300 | 300/360 | 200 | 4.0/4.8 |
| C-VLR400 | 385/462 | 250 | 5.5/6.5 |
| C-VLR500 | 500/600 | 250 | 7.5/9.0 |
| C-VLR1000 | 950/1140 | 200 | 9.0/11.0 |
| 18.5/22.0 |
VC-series oil-lubricated rotary vane vacuum pump models and technical specifications.
| Model | M3/Hr 50 / 60Hz |
Max Vacuum mbar Abs 50 / 60 Hz |
Motor Size Kw 50 / 60 Hz |
|
|---|---|---|---|---|
| 3PH | 1PH | |||
| VGC/A4 | 4.0/4.8 | 2.0/2.0 | 0.20/0.24 | |
| VGC/A6 | 6.0/7.2 | 2.0/2.0 | 0.32/0.38 | |
| VGC/A10 | 10.0/12.0 | 2.0/2.0 | 0.37/0.44 | |
| VGC/A15 | 15.0/18.0 | 2.0/2.0 | 0.55/0.65 | |
| VCB20 | 20/24 | 2.0/2.0 | 0.75/0.90 | |
| VCB25 | 22.5/26.5 | 2.0/2.0 | 0.75/0.90 | 1.10/0.00 |
| VCE15 | 15.0/18.0 | 10.0/10.0 | 0.55/0.65 | 0.75/1.30 |
| VCE25 | 25.0/30.0 | 10.0/10.0 | 0.75/0.90 | 1.00/1.30 |
| VCE40 | 40.0/48.0 | 10.0/10.0 | 1.10/1.30 | 1.50/1.80 |
| VCE60 | 60.0/72.0 | 10.0/10.0 | 1.50/1.80 | 2.20/0.00 |
| VCE100 | 100/120 | 10.0/10.0 | 2.20/3.00 | |
| VCA15 | 15.0/18.0 | 0.5/0.5 | 0.55/0.65 | 0.75/1.30 |
| VCA25 | 25.0/30.0 | 0.5/0.5 | 0.75/0.80 | 1.00/1.30 |
| VCA40 | 40.0/48.0 | 0.5/0.5 | 1.10/1.30 | 1.50/1.80 |
| VCA60 | 60.0/72.0 | 0.5/0.5 | 1.50/1.80 | 2.20/0.00 |
| VCA100 | 100/120 | 0.5/0.5 | 2.20/3.00 | |
| VCEH100 | 100/120 | 10.0/10.0 | 2.20/3.00 | |
| VCEH160 | 160/192 | 10.00/10.00 | 4.00/5.00 | |
| VCEH250 | 250/300 | 10.0/10.0 | 5.50/7.50 | |
| VCAH100 | 100/120 | 0.5/0.5 | 2.20/3.00 | |
| VCAH160 | 160/192 | 0.5/0.5 | 4.00/5.50 | |
| VCAH250 | 250/300 | 0.5/0.5 | 5.50/7.50 | |
| VC50 | 50/60 | 0.1/0.1 | 1.25/1.50 | |
| VC75 | 70/84 | 0.1/0.1 | 1.85/2.20 | |
| VC100 | 110/132 | 0.1/0.1 | 2.20/2.60 | |
| VC150 | 150/180 | 0.1/0.1 | 3.00/3.60 | |
| VC200/202 | 200/240 | 0.1/0.1 | 4.00/5.50 | |
| VC300/303 | 300/360 | 0.1/0.1 | 5.50/7.50 | |
| VC400 | 400/480 | 0.1/0.1 | 9.00/11.00 | |
| VC500 | 550/660 | 0.1/0.1 | 11.00.13.00 | |
| VC700 | 700/840 | 0.1/0.1 | 15.00/18.00 | |
| VC900 | 830/995 | 0.1/0.1 | 18.50/22.00 | |
| VC1100 | 1100/1320 | 0.1/0.1 | 22.0026.00 | |
| VC1300 | 1280/1535 | 0.1/0.1 | 30.00/36.00 | |
Yes. Send the complete model and electrical specification so we can confirm availability and prepare a quotation.
Many older pumps can still be serviced and supported with replacement vanes, filters and other parts. The technical tables on this page help identify older models.
VacAir Superstore provides workshop inspection, servicing and overhaul support for many dry-running, claw and oil-lubricated models.
Often, yes. The correct comparison depends on pumping speed, vacuum or pressure level, duty, motor, connections and application conditions.
Send a clear nameplate photograph showing the complete model, serial number, voltage, frequency and suffix letters.
Our experienced team can help with replacement pumps, new installations, servicing, spare parts and vacuum problems. Call us today for friendly technical advice and a competitive quotation.